INSTALLATION
Determine
correct GeoEdge size required.
GeoEdge size is determined by adding the depth of the bedding
layer and the paver thickness, subtracting 3/4” (19mm)
from the total, and then rounding to the nearest vertical
wall size.
Example:
3-1/8” (79.5mm) pavers on a 3” (76.2mm) layer
of bedding stone.
Bedding layer = 3” (76.2mm)
Paver height = 3-1/8” (79.5mm)
Paver height plus bedding layer = 6-1/8” minus 3/4”
= 5-3/8”.
....................................................155.7mm
minus 19mm = 136.7mm
Round to nearest GeoEdge vertical wall height = 5-1/2”
(139.7mm)
- Base
Preparation
Prepare sub-base and base course(s) to specification.
- Biaxial
GeoGrid - Tenax MS 220 B or Equal
Vehicular Application: Cut to a 6 foot (1.83
meter) width. Place 6 foot width by desired length over
base course along perimeter. A minimum of 5 feet (1.53
meters) under the pavers and 6”-12” (152-304mm)
extending to the outside of the paver installation. (Diagram
A)
Pedestrian Application: Cut to a 4 foot (1.22
meter) width. Place 4 foot width by desired length over
base course along perimeter. A minimum of 3 feet (0.91
meters) under the pavers and 6”-12” (152-304mm)
extending to the outside of the paver installation. (Diagram
A)
Geogrid Overlap. It is not necessary to overlap
the geogrid. For corners, a butt and pass method can be
utilized attaching the geogrid to the edge restraint along
both edges. For angles, cut the geogrid apron to fit within
the area and attach to the GeoEdge along the edges.
- GeoEdge
Installation
Establish specified elevation and perimeter of surface.
Set GeoEdge (base away from pavers) over geogrid at desired
perimeter. Fill gaps under GeoEdge with base material
to provide proper support. Connect sections on base and
sidewall using 1”x 2-3/4” (25.4mm x 70mm)
sliding connectors. (Crimping of sidewall connectors optional
using Permaloc Crimp Tool).
Capture Plates. Slide capture plates under the
GeoEdge base and geogrid. Align the inside edge of the
capture plate approximately in line with the vetical wall
of GeoEdge (Diagram B). Capture plate must overlap the
base of adjacent sections of GeoEdge.
Fasten GeoEdge to the capture plate using the pre-punched
holes in the edging. Fasten each plate with three 1/4”
- 14 x 1-1/4” (6.35mm - 14 x 31.75mm) hex washer,
self tapping galvanized screws. Tighten the screws to
securely compress the geogrid between the edging and capture
plates.
Space capture plates equidistant along the edging section
using 5 plates per eight foot section of edging.
Curves / Angles. The TRUTRAC base allows curves
and angles to be formed by removing the twist-and-snap
tabs. To form a curve, remove the appropriate tabs and
form the edging to the desired radius. Form curves before
attaching geogrid and capture plates.
-
Setting Course and Permeable Paver Installation
GeoEdge is designed to retain the full depth of the setting
course. Install setting course and permeable pavers per
specification.
-
Perimeter Backfill
It is critical to backfill and compact the perimeter.
Backfill adjacent material 1/2”– 3/4”
(12.7mm–19mm) below paver surface or as specified.
Backfill should extend beyond the edge restraint a minimum
of 12” (304mm).
NOTE: When installing Aluminum edging
in direct contact with ACQ treated lumber we recommend installing
a barrier material such as Grace Vycor® Deck Protector™.
If
you have any additional questions, please contact us at
1.800.356.9660 or email
us. |